Raised Floor Maximum Height

But it s not just the height.
Raised floor maximum height. Finished floor heights ffh or void the next decision you need to make is the height of the raised floor above your existing slab or sub floor. 600 mm 600 mm. The floor height is often determined by the design team early on in the process with other trades vying for space. Height effects form function in raised access floors.
In 2009 a separate category of raised floor was established by construction specifications institute csi and construction specifications canada csc to separate the similar but very different approaches to raised flooring. This raised floor pedestals can provide 20 mm 0 78 vertical adjustment. Raised floor became common as an effective cable management solution in commercial buildings schools labs universities corporate offices etc. High profile built in trunking system optional floor box specification.
Clearance must be adequate to accommodate interconnecting cables fiber cable raceways power distribution and any piping that is present under the floor. Depending on data center size and the amount of equipment that needs to be cooled a raised floor in today s world should be at least 18 inches high preferably 24 30 inches to hold the necessary cable bundles without impeding the high volumes of air flow needed to cool modern technology. In 2009 the csi and csa designated the following masterformat number and title for this newer generation of raised flooring systems. The raised floor height should be between 155 mm 6 in and 750 mm 30 in.
The maximum height of this system can be 200 mm. Raised floor pedestal hj 1 consists of a base plate threaded rod height adjustment head plate and hexagon nut. Regard to the weight capacity and load rating of the raised floor accessfloorstore com will give you the most detailed and in depth explanation with years of access floor manufacturing experience. For over 50 years the post and panel raised floor has been seen as a raised floor and it still serves the same purpose today.
And traditional post and panel raised floors require additional moveable parts and fasteners. For processors with multiple channels a minimum raised floor height of 305 mm 12 in is recommended. Stability in your raised floor is important. A project design team usually sees better results when the absolute maximum height is known up front and the actual floor height can be a dynamic value that may change as the electrical mechanical and it teams have their input.
This can be expressed as a finished floor height or as a clear void space. By identifying various applications avayo. Ultimate load to determine the maximum deflection s and permanent set s of an access floor under load. In the event you specify clear void space the thickness of the panel will be added to this figure to give the ffh.
09 69 33 low profile fixed height access flooring. Raised access floor height.